Ufc Command - AND Weighing Indicator AD-4407 Instruction Manual

Table of Contents

Advertisement

13.4.

13.4. UFC Command

13.4.
13.4.
UFC(Universal Flexi Coms) function enables editing the serial data output format
freely using the serial interface command.
For customizing the print out of the printer or efficient data collecting.
Output data is not only the indicator's data/status but also characters at will.
It can output the control code* of the printer. (* depends on the individual printer)
There are 2 set of memories for storing the parameters.
UFC Command Parameter
UFC Command Parameter
UFC Command Parameter
UFC Command Parameter
UFC commands such as SF1 have many parameters.
One command line can has a multiple number of parameters. Parameters are
stored in memory in order.
Multiple UFC commands are possible. The parameters are stored next to the last
parameter stored by the last UFC command.
Clear all of the data first, if storing a new set of parameters. The parameters in
the stored data can not be changed partially.
The various types of parameters and their descriptions are shown below.
data
$CL
$WT
$GR
$NT
$TR
$HD
$UT
$ST
$CP
$ID
$DN
$CD
$AN
$TL
$CM
$CR
$LF
$DE
$DL
AD-4407 Weighing Indicator
UFC Command
UFC Command
UFC Command
Weight, result of comparison etc.
Clear previous settings. UFC command parameters can not be
changed partially.
Displayed data
GRoss data
NeT data
TaRe data
HeaDer of Gross/Net/Tare or Preset tare. Refer to CF06.
Weight UniT
STable/Unstable
Result of ComParison
ID number specified at F06
Data Number increments with each output automatically
CoDe memory number
Accumulation count
TotaL weight
CoMma
CR code (0Dh)
LF code (0Ah)
DElete the last parameter
Inserting DeLay time (0.1 second step)
Example: DL10: 1.0 second delay