Counting Function; Using The Counting Function; Unit Weight Registration - AND Weighing Indicator AD-4407 Instruction Manual

Table of Contents

Advertisement

12. Counting Function

12.
Counting Function
12.
12.
Counting Function
Counting Function
This function determines the number of objects in a sample based on the unit
weight. Unit weight is stored one of the code memory data in non-volatile memory,
and is not lost even if the AC power supply is disconnected.

12.1. Using the Counting Function

12.1.
12.1.
12.1.
Preparation : Set f07 1 in the F-Functions.
Selects code memory number. Refer to "9.1.1. Using Code memory".
Register the unit weigh. Refer to "12.2.Unit Weight Registration".
Press the
to pcs
pcs.
pcs
pcs
In the counting mode, TARE, ZERO, NET/GROSS and other operations are the same
as that in the normal weighing mode.

12.2. Unit Weight Registration

12.2.
12.2.
12.2.
There are two methods to register the unit weight. One is to weigh the actual samples
for an unknown object's unit weight and the other way by digital input of the unit
weight by key or via the serial interface.
The unit weight is one item of the code memory data. Select the code memory
number and start the unit weight registration in the weight display or piece count
display. The unit weight registration can not be done from the code memory
number display.
There is not the counting accuracy improvement function by re-calculating the
unit weight based on the actual weight.
Weigh Actual Samples
When the unit weight is unknown, prepare some samples to determine the unit weight.
Step 1 Enter the counting mode.
Step 2 Press the
is displayed and unit pcs
samples. The right side of the display indicates the weight, 0 means that the
weight is zero and - means that the display is not at zero.
Step 3 Select the number of samples and place the samples specified on the weighing
sensor unit. Using following keys:
-
key..................The key to set the number of samples. Maximum is 9999.
0
9
key .....................The key to select the number of samples, 5, 10, 20, 50,100.
+/-
key................The key to set the zero point.
ZERO
key ................The key to tare. When using a container.
TARE
12. Counting Function
Using the Counting Function
Using the Counting Function
Using the Counting Function
key to enter the counting mode. The unit in the display changes
MODE
Unit Weight Registration
Unit Weight Registration
Unit Weight Registration
key to enter the unit weight registration. 5 0 or 5 -
SAMPLE
pcs blinks. the left side of the display is the number of
pcs
pcs
Page 44
AD-4407 Weighing Indicator

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents