Data Output
Item
f30
Data output
Analog Output
Item
f31
Output data
f32
Weight value at 4mA output
f33
Weight value at 20mA output
Serial Data Format
Item
f34
[Type3]
Serial data format 1
Initial value
19, 2e, 3a 4f e50
f35
[Type3]
Serial data format 2
Initial value
17 2f e30
1 Comma of the parameter display indicates that the comma (f46 0, semi-colon for
f46 1) is output after the data. To turn this mark on and off, press the
pressing
NET/GROSS
Output of initial settings of f34(19, 2e, 3a 4f e50) is like "ST,GR,+12345.6kg".
2 The data number *(parameter 3) increments automatically with each serial data
output from 1 to 99999 (the next after 99999 is 1). The starting number can be set
by the keys.
Press the
CODE(1)
changes to data r then r xxx. "xxx" is the next data number. Using the
enter the number and pressing the
weight display.
AD-4407 Weighing Indicator
*:
Initial settings.
Parameter
** 0
No data output
1
Analog output
2
Serial output
3
Serial output (Zero suppressing)
*:
Initial settings.
Parameter
* 0
Display data
1
Gross data
2
Net data
-999999 to 999999 (Initial setting is 0)
-999999 to 999999 (Initial setting is
10000)
Parameter
x 0
Terminator
x 1
Device ID (selected at f06)
x 2
Code number
x 3
Data number *
x 4
Result of comparison
x 5
(Reserved)
x 6
(Reserved)
x 7
Accumulated value
x 8
Accumulation count
x 9
Stable / Over
x a
Displayed weight
x b
Gross weight
x C
Net weight
x d
Tare weight
x e
Weight type (
x f
Weight unit (cf. Cf07)
key.
key while pressing the
Description
Description
Description
, refer to Cf06)
G /N / T
key at weight display, the display
PRINT
key to store the number and return to
ENTER
Page 27
Set f31, 32, 33
RS-232C,
RS-422/485
Polarity is
changed by
pressing the +/-
key.
key :
ZERO
Order of output
(1 to 999)
"Exxx" indicates
the end of data
to output
key:
NET/GROSS
Expand or
shorten output
data length
-
,
-
key:
0
9
A
F
output data
key while
9
-
keys to
0
9
6.2. F-Functions