Route and connect the drive cage bay 3 power cable (BP3) and the SAS cables to the drive cage
13.
backplane.
Install the fan cage.
14.
Install the air baffle.
15.
Install the access panel.
16.
Do one of the following:
17.
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
o
CAUTION:
all bays are populated with either a component or a blank.
Install the hard drives and hard drive blanks.
18.
Power up the server (on page 22).
19.

Six-bay LFF backplane option

When installing a single six-bay LFF backplane, HP recommends installing it in drive cage bay 1.
When installing a second six-bay LFF backplane, one of the following options is required:
An optional SAS controller
An optional 24-port SAS expander
To obtain either of these options, contact an HP authorized reseller.

Installing the six-bay LFF backplane (bay 1)

To install the component:
Power down the server (on page 22).