Two-Bay Lff Drive Cage Option - HP DL370 - ProLiant - G6 Performance User Manual

Hp proliant dl/ml370 g6 server user guide
Hide thumbs Also See for DL370 - ProLiant - G6 Performance:
Table of Contents

Advertisement

Power up the server (on page 22).
16.

Two-bay LFF drive cage option

To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the
jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page 21)."
To install the component:
Power down the server (on page 22).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
o
Extend the server from the rack (on page 24).
o
Remove the access panel (on page 25).
3.
Remove the air baffle (on page 26).
4.
Remove the fan cage (on page 26).
5.
Remove all SFF drives and drive cages, if installed.
6.
For more information, see the server maintenance and service guide.
Remove the media bay blank (on page 27).
7.
Remove the DVD-ROM drive (on page 28).
8.
Install the two-bay LFF drive cage.
9.
("Open or remove the tower
Hardware options installation 65
bezel" on page 22).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl370 g6Proliant ml370 g6

Table of Contents