If one fan fails in redundant mode, the server converts to non-redundant mode.
•
If two fans fail in redundant mode, the server shuts down.
WARNING:
To prevent personal injury from hazardous energy:
Remove watches, rings, or other metal objects.
•
Use tools with insulated handles.
•
•
Do not place tools or metal parts on top of batteries.
To install the component:
Power down the server (on page 22).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
o
Extend the server from the rack (on page 24).
o
Remove the access panel (on page 25).
3.
Remove the air baffle (on page 26).
4.
Remove the fan cage (on page 26).
5.
Remove the fan blanks from bay 1 and bay 3. Retain the blanks for future use.
6.
("Open or remove the tower
Hardware options installation 50
bezel" on page 22).