Ucd Timers; Ucd Ring Timer - Vodavi Starplus Triad-S System Programming Manual

Vodavi phone system programming manual
Hide thumbs Also See for Starplus Triad-S:
Table of Contents

Advertisement

UCD Timers

UCD Timers
RING
TIMER
NO-ANSWER
RECALL

UCD Ring Timer

Technical Manuals Online! - http://www.tech-man.com
Programming Steps
Press FLASH and dial [61]. The following message displays:
U CD T IMER S
EN TE R B U TTON N UM BE R
Description
Six timers for UCD operation are programmable on a system-wide basis.
The UCD timers include: a Ring Timer, Message Interval Timer, an
Overflow Timer, an Auto Wrap-Up Timer, a No/Answer Recall Timer, and a
No/Answer Retry Timer. Each timer is described in the following section
The buttons on the digital telephone are defined as shown when
entering the UCD Timers programming area:
MIT
TIMER
1
Q
NO-ANSWER
RETRY
5
T
Programming Steps
1. Press the RING TIMER flexible button (FLASH 61, Button #1). The
following message displays:
R ING
06 0
2. Enter a valid number on the dial pad which corresponds to
000-300 seconds.
3. Press HOLD to save the entry. A confirmation tone is heard and the
display updates.
OVERFLOW
TIMER
2
W
6
Y
0 00- 30 0
WRAP-UP
3
E
7
U
7-7
4
R
8
I

Advertisement