Setting The Configurable Link Timer; 1000Base-X Standard; Sgmii Standard; Simulating Auto-Negotiation - Xilinx LogiCORE 1000BASE-X User Manual

Logicore ip ethernet 1000base-x pcs/pma or sgmii v9.1
Table of Contents

Advertisement

R

Setting the Configurable Link Timer

The optional Auto-Negotiation function has a Link Timer (link_timer[8:0]) port. This
port sets the period of the Auto-Negotiation Link Timer. This port should be permanently
tied to a logical binary value, and a binary value should be placed on this port. The
duration of the timer is approximately equal to the binary value multiplied by 32.768
microseconds (4,96 clock periods of the 125 MHz clock provided to the core). See
Negotiation Signal Pinout" in Chapter
Note:
programming the Auto-Negotiation Link Timer when performing dynamic switching between
1000BASE-X and SGMI Standards.
The accuracy of this Link Timer is within the following range.

1000BASE-X Standard

The Link-Timer is defined as having a duration somewhere between 10 and 20
milliseconds. The example design delivered with the core sets the binary value as follows:
This corresponds to a duration of between 10.354 and 10.387 milliseconds.

SGMII Standard

The Link-Timer is defined as having a duration of 1.6 milliseconds. The example design
delivered with the core sets the binary value to
This corresponds to a duration of between 1.606 and 1.638 milliseconds.

Simulating Auto-Negotiation

Auto-Negotiation requires a minimum of three link timer periods for completion. If
simulating the Auto-Negotiation procedure, setting the link_timer[8:0] port to a low
value will greatly reduce the simulation time required to complete Auto-Negotiation.

Using the Auto-Negotiation Interrupt

The Auto-Negotiation function has an an_interrupt port. This is designed to be used
with common micro-processor bus architectures (for example, the CoreConnect bus
interfacing to MicroBlaze or the Virtex-II Pro embedded IBM PowerPC). For more
information, see
The operation of this port is enabled or disabled and cleared via the MDIO Register 16, the
Vendor-specific Auto-Negotiation Interrupt Control Register.
156
See
Chapter 11, "Dynamic Switching of 1000BASE-X and SGMII Standards"
+0 to -32.768 microseconds
100111101 = 317 decimal
000110010 = 50 decimal
"Auto-Negotiation Signal Pinout" in Chapter
When disabled, this port is permanently tied to logic 0.
When enabled, this port will be set to logic 1 following the completion of an Auto-
Negotiation cycle. It will remain high until it is cleared by writing 0 to bit 16.1
(Interrupt Status bit) of the
Interrupt Control," page
129.
www.xilinx.com
2.
"MDIO Register 16: Vendor Specific Auto-Negotiation
Ethernet 1000BASE-X PCS/PMA or SGMII v9.1
Chapter 10: Auto-Negotiation
"Auto-
for details of
2.