Interface Commands - Avery Dennison ALX 720 User Manual

Fully automatic print and apply machine
Hide thumbs Also See for ALX 720:
Table of Contents

Advertisement

Operators Manual
ALX 720
Factory
interface deactivated, at reactivation the parameters will be set to 8 data bits, 2
stop bits and no parity bit.

7.2 Interface commands

The below described commands will change one of the labelling parameter. The values are not
stored and will be lost when turning off power.
If the sequence nnnn is replaced by the character "?" then the current value of that parameter
will be returned by the labelling machine as a 4 character string confirming the name of the
parameter requested followed by 4 numbers representing the current value of that parameter.
The character 04H terminates all return messages.
Example
PC send the message:
Machine returns:
Command
#!APOSnnnn
#!APPLnnnn
#!APSFnnnn
#!APT1nnnn
#!APT2nnnn
#!APT3nnnn
#!ASTPnnnn
#!BANKnnnn
#!BLOWnnnn
#!COMPnnnn
#!CONTnnnn
#!DISTnnnn
#!EGRAnnn
#!LPITnnnn
4/09
#!VELO?
VELO0300<04H>
Description
Value APOS
Applicator type
APSF function
Applicator time
Applicator time
Applicator time
Value ASTP
Change product bank
Blow on time = APT 2
Automatic label compensation
Material contrast
Distance label sensor – dispensing
edge
Gear ratio
Label length
Page 82
Range
-0050 – 0100 mm
0000 direct dispense
0001 ASA
0002 EP
0003 EP_U
0004 PLUA
0005 INDX
0000 off
0001 on
0001 – 7500 ms
0001 – 7500 ms
0000 – 5000 ms
-0020 – 0050 mm
0000 - 0009
0001 - 7500 ms
0000 = Off
0001 = On
0001 – 0200
0000 automatically
0080 – 9999 * 0.1 mm
0300 – 1000
0005 – 0999 mm
0000 automatically
Remote programming

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents