Operators Manual
ALX 720
#!SP__
The machine is set to off. The product sensor is disabled and labelling will
therefore be stopped.
#!SR__
The machine is set to on. The product sensor is enabled and labelling can
restart.
#!XC Pharmacy Code ackn.
Pharmacy Code acknowledgement
#!XC delivers the data of the last printed pharmacy bar code. Delivery occurs in the
form:
xxxxxxxyyyyyyyy (Code content without checksum), with:
xxxxxxx = 7-digit CNK number
yyyyyyyy = 8-digit sequential number
If no pharmacy bar code was printed since the last printer reset, the delivery is
000000000000000.
For a full automatic operation, the following command sequence is required in case of an error:
#!ERRF
#!CLRE
#!SR__
7.3 Programming of printer functions
There are some general commands for programming the printer functions (head, temperature,
label dimension etc.). These are described in the EASY Plug manual. The special functions for
the machine are explained in the following table:
Command
#!/GAPn
#!/FMODn
4/09
Request error
Clear error message after fixing the error. The labeller shows „INIT"
Clear INIT message
Description
Gap function
Foil mode
Page 84
Range
0 = Auto
1 - 255 = manual value
1 = Continue
2 = Save
3 = None
Remote programming