5.2 Extended standard menu

The extended standard menu offers additional parameters you may use in your application. On
quitting this menu the current parameter settings are stored in memory. Further changes are
also written into memory. As long as this menu is active, no labelling is possible. By pressing
the key FEED, however, single dispense of labels is possible.
To enter the extended standard menu, proceed as follows:
Press the NEXT and PRIOR keys simultaneously.
After the display of CODE entert he password :
Press 1x PRIOR key
Press 2x NEXT key
Press 3x ENTER key
The display shows the first menu point.
Display
Function
LPIT
Label pitch
CONT
Label sensor contrast value
SENS
Sensor status
STOD
Stop position of label at the dispensing edge
PRDL
Product length (inhibit of further product- sensor
signals)
POS
Position of label on product
STAD
Delay time for start of applicator cycle
VELO
Labelling speed
STST
Check adjusted EGRA value
SLEW
Slew speed
EGRA
Electronic gear ratio adjustment
APT1
Dwell time for applicator
APT2
Blow on time for applicator
4/09
Page 47
Data value
AUTO/5...999 mm
AUTO/1...200
LAB or GAP
0.0 .... 200.0 (mm)
AUTO, 5 ... 999 mm
Up to 999.9 mm
1 ... 9999 ms
0.2 ... 30 m/min
see text
FAST or SLOW
100 to 500
1 ... 7500 ms
1 ... 7500 ms
Dispenser adjustment