10.3.2 OD Control sensor

Optional an OD control could be mounted to control the label roll. If the label material is nearly
empty the sensor gives an signal. A warning message and an output signal inform the personal
that in the next time the material has to be changed.
NPN sensor
brown
Supply
white
Signal+
grey
Signal-
blue
GND
E3JK-R2M2
Figure 25 NPN connection of optional ODC sensor
PNP sensor
brown
Supply
white
Signal+
grey
Signal-
blue
GND
S5-5-C8-30
Figure 26 PNP connection of optional ODC sensor