restart>reentry - Exit delay restarts when the door is
reopened during exit delay. The restart occurs once only.
Restarting the exit delay is helpful if the user re-enters
immediately after going out to retrieve an item that was left
behind.
door/fob/timer - When the door is closed, by pressing the
aux button on the keyfob*, or when the exit delay has
expired, whichever first.
* Only when defined as "skip exit delay" (see section
4.4.17).
ENTRY DELAY 1&2 [Fig 4.17.4(4)&(5)]
Two different entry delays allow the user to enter the
protected site (while the system is in the armed state) via 2
specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel
before the entry delay expires. Slow-rate warning beeps
start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate
increases. Locations No. 1 (entry delay 1) and 2 (entry
delay 2) allow you to program the length of these delays.
The options are: 30s, 45s, 60s , 3m and 4m.
32
ABORT TIME [Fig 4.17.4(6)]
Select the length of time allowed by the system to abort an
alarm (not applicable to alarms from FIRE, 24H SILENT,
EMERGENCY, GAS FLOOD and TEMPERATURE zones).
The PowerMaxExpress is programmed to provide an "abort
interval" that starts upon detection of an event. During this
interval, the buzzer sounds a warning but the siren remains
inactive and the alarm is not reported. If the user disarms
the system within the allowed abort interval, the alarm is
aborted.
The options are: abort time 15s, abort time 30s and abort
time 45s
ALARM CANCEL [Fig 4.17.4(7)]
Define the "cancel alarm" period that starts upon reporting
an alarm to the central station. If the user disarms the
system within that time period, a "cancel alarm" message
is sent to the central station.
The options are: in 5 minutes, in 15 minutes, in 60
minutes and in 4 hours.
D-303973 PowerMaxExpress Installer's Guide