READING ALARM MEMORY AND TROUBLE DATA

5. Reading Alarm Memory And Trouble Data

Reviewing Alarm/Tamper Memory

The PowerMaxComplete retains in its memory alarm
and "tamper" events that occurred during the last
arming period.
For PowerMaxComplete that includes partition
option: In order to review alarm and tamper events
of a specific partition, you need to select the desired
partition(s), (please refer to Partition Selection
Process in Chapter 2).
Note: Alarms enter the memory only after expiry of the
"abort period" (see Appendix A). This means that if you
disarm the system immediately - before the abort period
expires - there will be no memory indication.
A. Alarm / Tamper Indications
When the memory contains at least one event and
the system is in the disarmed state, a flashing
MEMORY message will be displayed as exemplified:
READY
(alternating)
READY
or, if the system is not ready for arming -
NOT READY
(alternating)
NOT READY
B. Investigating Alarm/Tamper Data
To review memory content, click the
button.
EXAMPLE 1: An alarm was triggered because the
garage door - zone No. 12 - opened but then re-
closed. In addition, the bedroom motion detector -
zone No. 7 - sent a "Tamper" message because its
cover had been removed.
PRESS
RESULTANT DISPLAY
READY
Z12 ALARMED
GARAGE DOOR
Z07 TAMPER-OPEN
BEDROOM
16
HH:MM
MEMORY
HH:MM
MEMORY
HH:MM
(alternating)
(alternating)
In response to additional clicking of
button, the display shows details of other events
retained in memory (if any), or reverts to its initial
state (see A above).
EXAMPLE 2: An alarm was triggered because the
garage door - zone No. 12 - opened and was left
open.
PRESS
RESULTANT DISPLAY
NOT READY
Z12 ALARMED
GARAGE DOOR
Z12 OPEN
GARAGE DOOR
Remember! The memory indication and content are
cleared upon the next arming of the system.

Reviewing Trouble Information

A. Trouble Indications
If TRBL flashes in the display, the TROUBLE
indicator illuminates, and 3 beeps are sounded once
per minute, you will have to investigate the system in
order to find out the origin and type of trouble. For
PowerMaxComplete
feature: The LCD will display the specific partition(s)
along with the specific zone number(s) of the location
of the trouble indication. The trouble types are as
follows:
SENSOR / KEYFOB / WIRELESS COMMANDER
TROUBLES
• Inactivity - No radio signals have been received
from a particular sensor / wireless commander (if
its supervision feature has been enabled) during a
pre-defined period.
• Low battery - The battery in a sensor, keyfob or
wireless commander is near the end of its useful life.
• "Clean me" - The fire detector must be cleaned.
• Gas trouble - Gas detector failure.
• Siren AC failure - There is no power to the siren.
GSM TROUBLES (if used)
• GSM line fail - GSM telephone line failure.
• GSM net fail - GSM network failure.
• RSSI low - The GSM received signal strength is low.
• GSM
communication
communication
(RS-232
PowerMaxComplete and GSM unit.
HH:MM
(alternating)
(alternating)
that
includes
partition
fail
-
There
is
format)
between
D-302213
no