Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The
options are Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of
occurences a duplicate event must happen before the MECI counter is incre-
mented. This is a numeric value. The default value is 1.
METW
The Multiple Event Time Window (METW) defines number of minutes must
pass between duplicate log events before MECI is incremented. This is in
minutes, from 0 to 99. The default value is 60.
View SmBIOS Event Log
This feature displays the contents of the SmBIOS Event Log.