X9SRH Motherboard Series User's Manual
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller)
LED connection for LAN port 1 is located
on pins 11 and 12 of JF1, and the LED
connection for LAN Port 2 is on Pins 9
and 10. NIC1 LED and NIC2 LED are
2-pin NIC LED headers. Attach NIC LED
cables to NIC1 and NIC2 LED indicators
to display network activities. Refer to the
table on the right for pin definitions.
Overheat (OH)/Fan Fail / UID LED
Connect an LED cable to the OH/Fan
Fail connections on pins 7 and 8 of JF1
to display signals or to provide advanced
warnings for chassis overheat/fan failure.
Refer to the table on the right for pin defi
nitions. The UID LED is used together with
the UID Switch.
A
B
C
OH/Fan Fail LED
Power Fail LED
20
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
Ground
Ground
2
2-22
Pin Definitions (JF1)
Pin# Definition
9/11
10/12
Pin# Definition
7
8
OH/Fan Fail Indicator
State Definition
Off
On
Flash-
ing
A. NIC1 LED
19
B. NIC2 LED
NMI
C. OH/Fan Fail / UID LED
X
Vcc
Vcc/UID Switch
Vcc
Vcc
Vcc/Blue UID LED
Vcc
#3~4
Reset Button
Power Button
#1~2
1
LAN1/LAN2 LED
Vcc
LAN Active
OH/Fan Fail LED
Pin Definitions (JF1)
Vcc/Blue UID LED
OH/Fan Fail LED
Status
Normal
Overheat
Fan Fail