Note
The mini-touch panel must be
installed with the release slot
located at the bottom.
Figure 10
AXM-MCA/PB and AC-RK
rack kit for an electronic
equipment rack
Color Active-Matrix LCD Mini-Touch Panels
Disconnect the AXlink connector from the AMX Control System, and the
6.
optional video wiring from the video source.
Thread the incoming AXlink and video wiring through the BB-MTP knockout.
7.
Fasten the BB-MTP to the plasterboard using the expansion screws supplied
8.
with the enclosure.
Connect the AXlink and video wiring to the mini-touch panel. Refer to Wiring
9.
the Mini-Touch Panels for wiring diagrams and printout descriptions.
Fasten the mini-touch panel to the BB-MTP with the #6-32 screws supplied with
10.
the enclosure.
Insert the engraved overlay back into the bezel.
11.
Connect the AXlink wiring to the AMX Control System, and video wiring to the
12.
video source. The mini-touch panel will beep when you apply power.
AXM-MCA (/PB) or AXM-MCV (/PB) (rack mount)
Mount the AXM-MCA (/PB), AXM-MCV (/PB), and AC-RK rack kit into an
electronic equipment rack. Figure 10 shows the AXM-MCA/PB and AC-RK
Accessory Rack Kit for an equipment rack.
Thread the incoming AXlink and video wiring through the opening in the
1.
equipment rack.
Disconnect the AXlink connectors from the AMX Control System, and the
2.
optional video wiring from the video source.
Connect the AXlink and video wiring to the mini-touch panel circuit card. Refer
3.
to Wiring the Mini-Touch Panels for wiring diagrams and pinout descriptions.
Insert the mini-touch panel into the equipment rack. Line up the top-left and
4.
bottom-right screw holes and start the #6-32 screws. Then, start the bottom-left
and top-right screws. Tighten all the screws after you start all the screws.
Installing Mini-Touch Panels