Indicator Lights at Startup
When the enclosure powers up, the indicator LEDs respond as follows:
Epica DGX 16 and 32 LED Indicators
Front
Rear –
Power
Supply
Rear –
CPU
* IOS (Initial Operating System) is the base layer operating system on AMX AutoPatch equipment. IOS performs
functions such as hosting higher level run-time software applications. When unexpected critical errors are
encountered within such hosted applications, system control of the equipment may be passed to the IOS layer
preventing normal system operation until the error is manually cleared. Please report all such errors to AMX
AutoPatch technical support (see page 42).
Important: If the indicator LEDs do not respond with a normal display as stated above, check power
connections, before contacting technical support (see page 42).
Important: When the system is powered down, be sure the indicator LEDs on the CPU are off and
the fans have stopped before reapplying power.
The system is ready to disconnect the factory default switch and to execute a test switch (see page 40) using
the control method of your choice.
TCP/IP Startup for NXB-AP-1000 Connection
If you have not already done so, attach the enclosure to a PC via the TCP/IP port (see page 42).

Serial Control Device Startup

If you have not already done so, attach the serial control device to the enclosure (see page 29) and open the
control program.
38
LED
Indicates
Power
System power
AC Power (
)
AC power present
DC Power (
)
DC power present
Temperature ( ) Power supply temperature
See page 25
Enc Link
• Speed status is either
• Green
100 Mbps (on)
or 10 Mbps (off)
• Amber
• Activity between enclosures
Status
System status
See page 42
TCP/IP
• Active server connection
• LED to left
• Active link status with server
• Link/Activity
• Speed status is either
• Speed
100 Mbps (on)
or 10 Mbps (off)
Normal Display
Constant green
Constant green
Constant green
Not illuminated
• Constant green
or not illuminated
• Blinks amber with activity
Constant green during power
up, then blinking green at 1
second on/off intervals
• Blinks green at 5 second
intervals (left of RJ-45)
• Blinks amber (left on RJ-45)
• Constant green or not
illuminated (right on RJ-45)
Epica DGX 16 and Epica DGX 32 Instruction Manual
Cautionary
Constant red: only
one power supply
is working
Not illuminated:
AC failure
Not illuminated:
DC failure
Amber: power
supply is over
temperature
Blinking red/green:
an exception has
been logged in IOS
(validation failure)
Blinking red: dropped
into IOS mode*