System Setup Options; Rack Installation And System Setup - AMX Epica DGX 16 Instruction Manual

Distribution matrix
Table of Contents

Advertisement

Installation and Setup

System Setup Options

The following table contains eight options for using DGX SC Optical and DGX DVI Boards in an
Epica DGX 16 or 32 Matrix Switcher in conjunction with DGX Fiber modules.
Note: DGX Fiber modules can also be used in a standalone, end-to-end solution; see the
"Instruction Manual – DGX Transmitters & Receivers."
System Setup Options – AMX AutoPatch Epica DGX Boards with DGX Fiber Modules
DGX Fiber Module
HD-15 TX
DVI TX
Not Applicable
Not Applicable
HD-15 TX
HD-15 TX
DVI TX
DVI TX
A typical system setup is illustrated on page 49 and shows an Epica DGX 32 with DGX SC Optical
Boards used in conjunction with DGX TX and DGX RX modules.
The DGX HD-15 TX and the DGX DVI TX modules can be installed interchangeably. The
DGX HD-15 RX and the DGX DVI RX modules are interchangeable as well, providing for an
extremely flexible system. For example, in the same system, a source device can send a DVI signal and
the destination device(s) can receive an RGBHV signal.
Note: In addition to the system setup options listed in the table above, optical signal flow between
Epica DGX 16, 32, and 144 enclosures is supported. Contact your AMX representative for these and
other system design possibilities.

Rack Installation and System Setup

Epica DGX 16 and 32 enclosures can be mounted in a standard EIA 19 in. (48.26 cm) rack.
Required Items for Rack Installation:
Optional Items for Rack Installation:
Installation Recommendations:
20
Epica DGX Input Board
SC Optical
SC Optical
DVI
DVI
SC Optical
SC Optical
SC Optical
SC Optical
Enclosure
Standard EIA 19 in. (48.26 cm) rack
Screwdriver
Screws that fit your rack for mounting the enclosure
Power cords (2)
Surge-protector – highly recommended
A PC or laptop computer with a null modem cable for communication with the enclosure via
the RS-232 serial (Control) port
Write the serial number (normally located on rear of enclosure) in an easily accessible
location before installing the enclosure in a rack.
Use an earth-grounded power cord / system with an Epica DGX 16 or 32.
Attach all power cords to a single surge protector and/or an AC line conditioner.
Apply power to the Epica DGX 16 or 32 enclosure before applying power to its source
and destination devices.
Epica DGX Output Board
DGX Fiber Module
DVI
Not Applicable
DVI
Not Applicable
SC Optical
HD-15 RX
SC Optical
DVI RX
SC Optical
HD-15 RX
SC Optical
DVI RX
SC Optical
HD-15 RX
SC Optical
DVI RX
Epica DGX 16 and Epica DGX 32 Instruction Manual