Replacement Parts
To remove the cabinet
To remove the cabinet
Turn off the oscilloscope and disconnect the power cable.
1
If a module is installed, remove it from the oscilloscope.
2
Using the T15 TORX driver, remove the two screws from the rear of
3
the cabinet.
Using your thumbs, gently push on the rear-panel connector to slide
4
the oscilloscope out of the cabinet.
To remove the fan
Disconnect the fan cable from the power supply board.
1
Using the T15 TORX driver, remove the three screws that hold the
2
fan to the deck.