To Enter Programming Commands

Refer to the HP 8590 E-Series and L-Series Spectrum Analyzer and HP 8591C Cable TV
Analyzer
Programmer's hide
1. Press cF8_1 on the external keyboard to enter the mode for executing remote commands.
2. Type in a programming command (for example, type
3. Press [ENTER_) on the external keyboard to execute the command.
Note
Unlike entering a remote programming command using an external controller,
entering the remote programming commands with the external keyboard does
not require including the spectrum analyzer address. It is also not necessary to
terminate the programming line with a semicolon. However, semicolons are
necessary for separating the programming commands. For example, a program
line is entered via the external controller as:
CF 300MHZ;SP lMHZ;[ENTERj.
After IF8) is pressed, the spectrum analyzer remains in command mode. To return to the title
entry mode, press m (on the external keyboard).

To Enter a Prefix

Refer to the HP 8590 E-Series and L-Series
Analyzer Programmer's Guide for more information.
1. Press IF7] on the external keyboard to enter the mode for entering a prefix.
2.
Type in the prefix.
3. Press [ENTER] on the external keyboard.
for more information.
IP).
Analyzer and HP 8591C Cable TV
Spectrum
OUTPUT 718; "CF 300MHZ; SP
Using Analyzer Features 5.43

Hide quick links: