accesses the softkey menu of functions that can be coupled. (Coupled
functions are functions that are linked: if one function is changed, the other
function is changed.) The functions that can be auto-coupled are listed below:
Video bandwidth couples to resolution bandwidth when the spectrum
n
analyzer has a video-bandwidth to resolution-bandwidth ratio of 0.3.
Sweep time couples to span, resolution bandwidth, and video bandwidth.
n
RF attenuation couples to reference level.
n
During normal operation, the sweep time, resolution bandwidth, and video
bandwidth are coupled to yield optimum performance. If any of these
functions becomes uncoupled (that is, is manually set), a "#" will appear next
to the screen annotation representing the function on the screen.
If one or more functions are manually set so that the amplitude or frequency
becomes uncalibrated,
Recouple a single function by pressing the function label (to activate the
function), and pressing the function again so that AUTO is underlined.
Pressing
AUTO qP
AT MKR
executes a quasi-peak routine. See the HP 85913, HP 85933, HP 85943,
HP 85953, or HP 85963 Option 103 supplement documentation for more
information.
Front-Panel Key Access: t-1
Aux Conn
accesses the softkey menu used to control the auxiliary outputs and input.
Control
The auxiliary outputs are controlled by pressing CNTL A 0 1 ,
CNTL C 0
(control line I), can be displayed on the spectrum analyzer screen with
DISPLAY CNTL I.
Front-Panel Key Access: (AUXJ
accesses the softkey menu used for control of the auxiliary interface
connector.
generator function. Fbr Option 102 or 103: [AUXj accesses demodulation
functions. For Option 010 or 011: it accesses tracking generator functions.
HP 8590L or HP 8591 E on1 y.
AUXB
displays the voltage level present at an unused input to the Test Point MUX
circuitry located on the A7 Analog Interface assembly. This is a service
diagnostic function and is for service use only.
Front-Panel Key Access: (CAL)
copies trace B into trace C.
Front-Panel Key Access: [Wj
B <-->
exchanges the contents of trace B with trace C and puts trace B in view mode.
Front-Panel Key Access: (mj
subtracts the display line from trace B and places the result in trace B. The
B-DL + B
description for information about math operations.
Front-Panel Key Access: [WI
appears on the right side of the graticule.
AUTO ALL
couples all coupled functions listed.
CNTL
1 , and
D 0
1 . The status of the auxiliary input
CNTL B 0
1 ,
OFF