ZRETRY
ZSYNCS
ZTEST-INTVL
ZTHRES
ZTIMEOUT
ZXLATE
ZXPARENT
An integer that specifies the number of times the
TR3271 retransmits data as a result of data link
errors before returning an error.
be in the 1 through 14 range.
An integer that specifies the number of SYN
characters that precede each frame.
must be in the 1 through 14 range.
is 3.
A timestamp that specifies the interval, in .01
seconds, at which the status probe is issued to
the CLIP.
The value must be in the range 0
through 5:27:67.
probe will be issued.
seconds).
An integer that specifies the statistics thresh-
old values.
This value defines the number of
frames to be transmitted and received before line
quality is checked.
0 through 32767 range.
threshold is ignored.
A timestamp that specifies the line I/O timeout
value, in .01 seconds.
long the I/O process waits before retrying when
a data link error occurs.
the range 00:00.6 through 00:10.
00:02.7.
A Boolean variable that specifies whether the
TR3271 subsystem translates inbound and outbound
data.
If the value is ZSPI-VAL-TRUE, the TR3271
subsystem translates inbound data (from the line)
from EBCDIC to ASCII, and translates outbound
data (to the line) from ASCII to EBCDIC.
the value is ZSPI-VAL-FALSE, the TR3271 subsystem
does not translate characters.
ZSPI-VAL-TRUE.
if ZXLATE-IN and ZXLATE-OUT, as well as ZCHAR-SET
(value EBCDIC) and ZCTL-SET (value EBCDIC), are
used.
A Boolean variable that controls transparent-
text mode for the named line.
ZSPI-VAL-TRUE, transparent-text mode is enabled
for the line; if the value is ZSPI-VAL-FALSE,
it is not.
The default is ZSPI-VAL-FALSE.
Transparent-text mode can only be enabled if the
line is configured with the EBCDIC character set.
COMMANDS AND RESPONSES
The default is 3.
If the value is 0, no status
The default is :10 (10
The value must be in the
If the value is 0, the
The default is 0.
This value defines how
The value must be in
The value of ZXLATE must be TRUE
If the value is
ALTER Command
The value must
The value
The default
The default is
If
The default is