Modules
Table 7 - 3
RAID Verification &
7
Repair Status
7 - 12 Intel Rapid Storage Technology
RAID Volume Data Verification and Repair
The RAID volume data verification process identifies any inconsistencies or bad
data on a RAID 0 or RAID 1 volume. The table outlines what occurs for each RAID
level:
RAID Level
RAID 0
Bad blocks are identified.
Bad blocks are identified.
RAID 1
Data on the mirrored drive is compared
to data on the source drive.
Bad blocks are identified.
RAID 5
Parity is recalculated and compared to
the stored parity for that stripe.
Replacing and Reverting Recovery and Master Volumes
If a master or recovery drive fails you will need to add a new identical drive and re-
build the recovery volume to the drive. You can also revert the master drive to the
state of the previous volume update. For details on how to do this see the help file
"Intel® Rapid Storage Technology Help" on page 7 -
how to verify and repair RAID volume data. Verification will identify and repair
data inconsistencies on the volume.
Verify
N/A
Bad blocks are reassigned.
If the data on the mirrored drive does not
match the data on the source drive, the
data on the mirrored drive is overwritten by
the data on the source.
Bad blocks are reassigned.
If the newly calculated parity does not
match the stored parity, the stored parity is
overwritten with the newly calculated parity.
Verify & Repair
11. See over for details on
Need help?
Do you have a question about the Notebook V11.6.00 and is the answer not in the manual?