SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL OWF51
Specifications
Service Flow Rate (maximum) ...............................................0.75 GPM (2.83 L/min)
Rated Service Life OWF50-NI300 (maximum) ......................300 gallons (1135 liters)
Rated Service Life OWF50-WI500 (maximum) ......................500 gallons (1892 liters)
Maximum Operating Temperature..........................................100° F (38° C)
Minimum Operating Temperature...........................................33° F (1° C)
Minimum Pressure Requirement............................................35 psi (138 kPa)
Maximum Operating Pressure ...............................................120 psi (827 kPa)
PERFORMANCE DATA
Substance
Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent Challenge
Concentration
0.15 mg/L +/- 10%
0.15 mg/L +/- 10%
Minimum 50,000/L
11+/-1 NTU
0.002 mglL +/- 10%
0.009 mg/L +t- 10%
2.0 mglL +I- 10%
at least 10,000
particles/mL
0.210 mgtL +/- 10%
107 to108 fibers/L: fibers greater
thant0 micrometers inlength
Effluent
Average %
Maximum
Average
Reduction
Effluent
0.001 mg/L
99.33%
0.001 mg/L
0.002 mg/L
98.66%
0.003 mg/L
lcount/mL
99.99%
3 count/mL
0.12 NTU
98.98%
0.18 NTU
0.00005 mg/L
97.62%
0.00005 mg/L
0.0002 mg/L
97.93%
0.0006 mg/L
0.09 mgtL
95.26%
0.17 mg/L
900 count/mL
99.68%
2400 count/mL
45.45 ug/L
84.42%
100 ug/L
0.16 MFL/mL
99.96%
0.16 MFL/mL
Min, Required Inlet
Reduction
pH
0.010 mg/L
6.5
0.010 mg/L
8.5
> 99.95%
NA
0.5 NTU
NA
0.00002 mg/L
NA
0.003 mg/L
NA
_>75%
NA
_>85%
NA
0.0017 mg/L
NA
99%
NA
* Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under
standard laboratory conditions, however, actual performance may vary. Health Claim Performance test-
ed and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 -1 microns.
Trademark/Model
Desiqnation
State of California
Department
of Heallb
Services
Water
Trealment
Device
Certificate Namber
01 - 1486
Date
Issued:
Scptm_aber
2t.
2(X)l
Date
Revised:
March
20, 2(X)2
Replacement
Elements
500 gal
300 ga]
5O0 gal
300 gal
500 ga]
300 gal
GENERAL USE
CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this unit with
your actual water treatment needs.
DO NOT use this product where water
is microbiologically
unsafe or of
unknown quality without adequate
disinfection before or after the sys-
tem. System certified for cyst reduc-
tion may be used on disinfected water
that may contain filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The retractable water filtration system
uses a OWF51 replacement cartridge.
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer to
the applicable section in this owner's
manual for general operation, mainte-
nance requirements and troubleshooting.
Replacement Elements: OWF51
This system has been tested according to
ANSI/NSF 42 and 53 for reduction of the
substances listed below. The concentra-
tion of the indicated substances in water
entering the system was reduced to a
concentration less than or equal to the
permissible limit for water leaving the sys-
tem, as specified in ANSI/NSF 42 and 53.
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models OWF50-Wl500 and OWF50-NI300 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turb d ty and Asbestos Reduct on
1000ApolloRoad
Eagan,MinnesotaU.S.A.
EPAEST#35917-MN-1
Rated
Service
Flow:
0 75