Operation; Low Oil Level Switch; Intermittent Duty Formula; Filling Procedures - Ingersoll-Rand 2475N7.5-P Owner's Manual

Standard two-stage lubricated air compressors electric motor and gasoline engine models up to 30 horsepower)
Table of Contents

Advertisement

Available languages

Available languages

Seethe petroleum lubricant viscosity table below. The table is
intended asa general guide o nly. Heavy duty operating conditions
require heavier viscosities.
Refer specific operating conditions
to
Ingersoll-Rand
forrecommendations.
Temperature
Around
Compressor
oF
oC
< 40
< 4.4
40-80
4.4-26.7
80-125"
26.7-51.0"
Viscosity @ 100°F
(37.8°C)
SUS
I
Centistokes
150
32
500
110
750
165
Viscosity Grade
ISO
I
SAE
32
10
100
30
150
40
* = For Models
2000 and 2000P, use Ingersoll-Rand
XL-740HT
Compressor
Oil in temperatures
above 100°F
(37.7°0).
If you use a petroleum-based
compressor
lubricant
at start-up and
decide
to convert to All Season T30 Select
later on, the pump must
be decarbonized
and flushed
before conversion.
Contact
Ingersoll-Rand
for more information.
FILLING
PROCEDURES:
1.
Unscrew and remove the oil fill plug.
2.
Fill the crankcase with lubricant.
3.
Replace the oil fill plug HAND TIGHT ONLY.
/_ CAUTION
Do not remove the oil fill plug while the compressor
is running,
Refer to the following
table for crankcase
capacity.
Model
Crankcase
Capacity
2340
28 oz.(827
ml.)
2475
41 oz.(1212
ml.)
2545
73 oz.(2158
ml.)
7100
80 oz.(2365
ml.)
15T, 2000,2000P
144 oz.(4258
ml.)
Use one of the following
methods
illustrated
to determine
when the
crankcase
is full,
A
E
F
A = FULL level at bottom thread of oil fill opening on units without
sight glass or dipstick.
B = ADD level below bottom thread of oil fill opening on units
without sight glass or dipstick.
C = FULL level on units with sight glass.
D = ADD level
on units with sight glass.
E = ADD level on units with dipstick.
F = FULL level on units with dipstick.
LOW
OIL LEVEL
SWITCH
A float activated
low oil level switch may be installed to protect your
unit against
damage
due to insufficient compressor oil level. Low oil
level in the compressor crankcase causes the switch contacts to
open, thus shutting
the unit down until the proper oil level has been
restored.
Proper protection
against
low oil level depends on proper
adjustment
of the low oil level switch. During the initial run, stop the
unit and drain one quart of oil from the compressor
crankcase
into a
suitable
clean container.
Listen for the switch to click or check the
switch with a continuity
tester.
The float sometimes
gets cocked or stuck during shipping.
If the
float is cocked or stuck, open the disconnect
switch,
drain the
remaining
oil, remove the crankcase
cover and then free the float.
Reassemble
and then reuse the same oil.
NOTE
If the float is cocked in the low position, the unit
cannot start.
INTERMITTENT
DUTY
FORMULA
Units operating above 200 PSIG are to be operated according to the
"Intermittent
Duty Formula."
INTERMITTENT
DUTY FORMULA
Pump-up
time should
not ordinarily
exceed thirty (30)
minutes
or be less than ten (10) minutes.
Shutdown
periods
between
cycles of operation
should be at least
equal to the pump-up
time. Note: When the compressor
is regulated
by constant
speed control,
the shutdown
period
is the time the compressor
is operating
unloaded.
A pump-up
time limit with the following
cool-down
period is
recommended
to protect the valves and heads against
stabilized
high operating
temperatures,
which could rapidly build up carbon in
these areas.
All inquiries for high-pressure
compressor
application
where the
"use" cycle differs from the "Intermittent
Duty Formula"
should be
referred
to Ingersoll-Rand.
START-UP
(ELECTRIC
MOTOR DRIVEN MODELS)
__
1, Close the service valve.