Rise Time: Time that the leading edge of the first pulse in the waveform takes to
rise from 10% to 90% of its amplitude.
Fall Time: Time that the falling edge of the first pulse in the waveform takes to
fall from 90% to 10% of its amplitude.
+Width: The width of the first positive pulse in 50% amplitude points.
-Width: The width of the first negative pulse in the 50% amplitude points.
Delay 1→2 : The delay between the two channels at the rising edge.
Delay 1→2 : The delay between the two channels at the falling edge.
+Duty: +Duty Cycle, defined as +Width/Period.
-Duty:-Duty Cycle, defined as -Width/Period.

How to Measure with Cursors

Press the Cursor button to display the cursor measurement function menu (CURS
MEAS) in the screen.
The Cursor Measurement for normal mode:
The cursor measurement includes Voltage Measurement and Time Measurement
at normal mode, shown as Figure 5-60.
The description of the cursor measurement menu is shown as the following table:
5.Advanced User Guidebook
Figure 5-59
Figure 5-60 CURS MEAS Menu