Owon SDS-E Series Quick Manual
Hide thumbs Also See for SDS-E Series:

Advertisement

Quick Links

General Warranty
OWON warrants that the product will be free from defects in materials and workmanship
for a period of 3 years from the date of purchase of the product by the original purchaser
from the OWON Company. And the warranty period of accessories such as probe is 12
month. This warranty only applies to the original purchaser and is not transferable to the
third party. If the product proves defective during the warranty period, OWON either will
repair the defective product without charge for parts and labor, or will provide a
replacement in exchange for the defective product. Parts, modules and replacement
products used by OWON for warranty work may be new or reconditioned like new
performance. All replaced parts, modules and products become the property of OWON.
In order to obtain service under this warranty, Customer must notify OWON of the defect
before the expiration of the warranty period. Customer shall be responsible for packaging
and shipping the defective product to the service center designated by OWON, and with a
copy of customer proof of purchase.
This warranty shall not apply to any defect, failure or damage caused by improper use or
improper or inadequate maintenance and care. OWON shall not be obligated to furnish
service under this warranty a) to repair damage resulting from attempts by personnel other
than OWON representatives to install, repair or service the product; b) to repair damage
resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-OWON supplies; or d) to service a
product that has been modified or integrated with other products when the effect of such
modification or integration increases the time or difficulty of servicing the product.
Please contact the nearest OWON's Sales and Service Offices for services or a complete
copy of the warranty statement.
For better after-sales service, please visit
www.owon.com.cn
and register the purchased
product online.
Excepting the after-sales services provided in this summary or the applicable warranty
statements, OWON will not offer any guarantee for maintenance definitely declared or hinted,
including but not limited to the implied guarantee for marketability and special-purpose
acceptability. OWON should not take any responsibilities for any indirect, special or consequent
damages.

Advertisement

Table of Contents
loading

Summary of Contents for Owon SDS-E Series

  • Page 1 3 years from the date of purchase of the product by the original purchaser from the OWON Company. And the warranty period of accessories such as probe is 12 month. This warranty only applies to the original purchaser and is not transferable to the third party.
  • Page 2: Table Of Contents

    Table of Contents 1. General Safety Requirements ..................1 2. Safety Terms and Symbols ....................2 3. Quick Start ........................4 Introduction to the Structure of the Oscilloscope ..............4 Front Panel ............................... 4 Right Side Panel ............................5 Rear Panel ..............................6 Control (key and knob) Area ........................
  • Page 3: General Safety Requirements

    1. General Safety Requirements 1. General Safety Requirements Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage. In order to avoid any contingent danger, this product is only used within the range specified.
  • Page 4: Safety Terms And Symbols

    2. Safety Terms and Symbols 2. Safety Terms and Symbols Safety Terms Terms in this manual. The following terms may appear in this manual: Warning: Warning indicates the conditions or practices that could result in injury or loss of life. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property.
  • Page 5 2. Safety Terms and Symbols To avoid body damage and prevent product and connected equipment damage, carefully read the following safety information before using the test tool. This product can only be used in the specified applications. Warning The two channels of the oscilloscope are non-isolated electrically. The channels should adopt common basis during measuring.
  • Page 6: Quick Start

    3. Quick Start 3. Quick Start Introduction to the Structure of the Oscilloscope When you get a new-type oscilloscope, you should get acquainted with its front panel at first and the digital storage oscilloscope is no exception. This chapter makes a simple description of the operation and function of the front panel of the oscilloscope, enabling you to be familiar with the use of the oscilloscope in the shortest time.
  • Page 7: Right Side Panel

    3. Quick Start Right Side Panel Figure 3-2 Right side panel 1. USB Host port: It is used to transfer data when external USB equipment connects to the oscilloscope regarded as "host device". For example: use this port to save waveform file into USB flash disk.
  • Page 8: Rear Panel

    3. Quick Start Rear Panel Figure 3-3 Rear Panel 1. Handle 2. Air vents 3. AC power input jack 4. Fuse 5. Foot stool (which can adjust the tilt angle of the oscilloscope)
  • Page 9: Control (Key And Knob) Area

    3. Quick Start Control (key and knob) Area Figure 3-4 Keys Overview 1. Menu option setting: H1 - H5 2. Menu option setting: F1 - F5 3. Menu off:turn off the menu ○ 4. M knob (Multipurpose knob): when a M symbol appears in the menu, it indicates you can turn the M knob to select the menu or set the value.
  • Page 10: User Interface Introduction

    3. Quick Start User Interface Introduction Figure 3-5 Illustrative Drawing of Display Interfaces (SDS5032E(V) shown) Waveform Display Area. 2. The state of trigger, including: Auto: Automatic mode and acquire waveform without triggering. Trig: Trigger detected and acquire waveform. Ready: Pre-triggered data captured and ready for a trigger. Scan: Capture and display the waveform continuously.
  • Page 11 3. Quick Start 13. The frequency of the trigger signal of CH1. 14. It indicates the current function menu. 15. Current trigger type: Rising edge triggering Falling edge triggering Video line synchronous triggering Video field synchronous triggering The reading shows the trigger level value of the corresponding channel. 16.
  • Page 12: How To Implement The General Inspection

    Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with the distributor of OWON responsible for this service or the OWON's local offices.
  • Page 13: How To Implement The Probe Compensation

    3. Quick Start Connect the probe tip and the ground clamp to the connector of the probe compensator. 3. Press the "Autoset" Button. The square wave of 1 KHz frequency and 5V peak-peak value will be displayed in several seconds (see Figure 3-6). Figure 3-6 Auto set Check CH2 by repeating Step 2 and Step 3.
  • Page 14: How To Set The Probe Attenuation Coefficient

    3. Quick Start Overcompensated Compensated correctly Under compensated Figure 3-7 Displayed Waveforms of the Probe Compensation Repeat the steps mentioned if needed. Figure 3-8 Adjust Probe How to Set the Probe Attenuation Coefficient The probe has several attenuation coefficients, which will influence the vertical scale factor of the oscilloscope.
  • Page 15: How To Use The Probe Safely

    3. Quick Start Figure 3-9 Attenuation Switch Caution: When the attenuation switch is set to 1X, the probe will limit the bandwidth of the oscilloscope in 5MHz. To use the full bandwidth of the oscilloscope, the switch must be set to 10X. How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock, shown as Figure 3-10.
  • Page 16: Introduction To The Vertical System

    3. Quick Start Cal"; run the program after everything is ready. Introduction to the Vertical System As shown in Figure 3-11, there are a few of buttons and knobs in VERTICAL CONTROLS. The following practices will gradually direct you to be familiar with the using of the vertical setting.
  • Page 17: Introduction To The Horizontal System

    3. Quick Start menu, symbols, waveforms and scale factor status information of the corresponding channel will be displayed in the screen. Introduction to the Horizontal System Shown as Figure 3-12, there are a button and two knobs in the "HORIZONTAL CONTROLS".
  • Page 18: How To Measure Automatically

    3. Quick Start Figure 3-13 Trigger Control Zone 1. Press the "Trigger Menu" button and call out the trigger menu. With the operations of the menu selection buttons, the trigger setting can be changed. 2. Use the "TRIG LEVEL" knob to change the trigger level setting. By rotating the "TRIG LEVEL"...
  • Page 19: How To Use Autoscale

    3. Quick Start voltage of the CH2, following the steps below: 1. Press the Measure button to show the automatic measurement function menu. 2. Press the H1 button to display the Add menu. 3. Press the F2 button and choose CH1 as the source. 4.
  • Page 20: Communication With Pc

    4. Communication with PC 4. Communication with PC Digital storage oscilloscope support communications with a PC through USB, LAN or COM port. You can use the Oscilloscope communication software to store, analyze, display the data and remote control. Here is how to connect with PC. First, install the Oscilloscope communication software on the supplied CD.
  • Page 21: Using Lan Port

    Here we set the IP address to 192.168.1.71. Figure 4-2 Set the network parameters of the computer (3) Set the network parameters of the OWON Oscilloscope Software. Run the software on the computer; choose the "Ports-settings" of the "Communications" menu item.
  • Page 22: Connect Through A Router

    4. Communication with PC Figure 4-3 Set the network parameters of the OWON Oscilloscope Software (4) Set the network parameters of the oscilloscope. In the oscilloscope, press the Utility button and press H1 button, turn the M knob to select the LAN Set; press the H2 button, the set menu is displayed on the right.
  • Page 23 192.168.1.1. Figure 4-5 Set the network parameters of the computer (3) Set the network parameters of the OWON Oscilloscope Software. Run the software on the computer; choose the "Ports-settings" of the "Communications" menu item. Set "Connect using" to LAN. About the IP, the first three bytes is same as the IP in the step (2), the last byte should be different.
  • Page 24: Using Com Port

    4. Communication with PC (4) Set the network parameters of the oscilloscope. In the oscilloscope, press the Utility button and press H1 button, turn the M knob to select the LAN Set; press the H2 button, the set menu is displayed on the right. Set the IP and the Port to the same value as the "Ports-settings"...
  • Page 25: Appendix

    4K, mass storage USB disk is also supported. If the USB disk doesn't work properly, format it into the supported format and try again. About the methods to format the USB disk, refer to SDS-E Series Smart Digital Storage Oscilloscopes User Manual. Sep. 2016 edition V1.6.0...

This manual is also suitable for:

Sds7122eSds7102eSds7072eSds6062eSds5052e