Table 1-2. LCD Status Messages (Optional)
Code
Text
W1628
Performance
degraded.
Check PSU and
system
configuration.
W1630
Power supply
redundancy
degraded.
Check PSU
cables.
NOTE:
For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
(continued)
Causes
The system configuration
requires more power than
what the power supply can
provide, but it can boot if
throttled.
The power supply
subsystem is no longer
fully redundant.
Corrective Actions
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Reseat the power
supplies. See
"Troubleshooting Power
Supplies" on page 155.
If the problem persists,
see "Getting Help" on
page 181.
About Your System