Dell PowerEdge R415 Owner's Manual page 38

Server system
Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional)
Code
Text
E2112
Memory spared
on DIMM ##.
Power cycle
AC.
I1910
Intrusion
detected.
Check chassis
cover.
I1912
SEL full.
Review & clear
log.
I1920
iDRAC6 Upgrade
Successful
W1228
RAID
Controller
battery
capacity <
24hr.
W1627
Power required
> PSU wattage.
Check PSU and
config.
38
About Your System
(continued)
Causes
The system BIOS has
spared the memory
because it has determined
the memory had too many
errors. "##" represents the
memory module
implicated by the BIOS.
System cover has been
removed.
The SEL is full of events
and is unable to log any
more.
Optional iDRAC6 has
been upgraded
successfully.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
The system configuration
requires more power than
what the power supply can
provide.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 157.
Information only.
Check the SEL for details
on the events, then clear
the SEL.
Allow RAID battery to
charge to greater than
24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 121.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents