Dell PowerEdge R415 Owner's Manual page 33

Server system
Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional)
Code
Text
E1810
Hard drive ##
fault. Review
& clear SEL.
E1812
Hard drive ##
removed. Check
drive.
E1920
iDRAC6 Upgrade
Failed
E1A11
PCI Riser
hardware &
configuration
mismatch.
Reconfigure.
E1A12
PCI Riser not
detected.
Check Riser.
E1A14
SAS cable A
failure. Check
connection.
(continued)
Causes
The specified hard-drive
has experienced a fault.
The specified hard-
drive has been removed
from the system.
The iDRAC6 Express card
is not installed properly or
the card is bad.
PCIe risers are not
configured correctly.
Some invalid
configurations prevent the
system from powering on.
One or both of the PCIe
risers are missing. This
prevents the system from
powering on.
SAS cable A is missing
or bad.
Corrective Actions
See "Troubleshooting a
Hard Drive" on page 163.
Information only.
Reseat the iDRAC6
Express Card. See
Installing an iDRAC6
Express Card. If the
problem persists, see
"Getting Help" on
page 181.
Reinstall the expansion-
card riser. See "Expansion
Card and Expansion-
Card Riser" on page 99.
If the problem persists,
the riser card or system
board is faulty. See
"Getting Help" on
page 181.
Reinstall the missing
riser. See "Expansion
Card and Expansion-
Card Riser" on page 99.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 181.
About Your System
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents