Dell PowerEdge R415 Owner's Manual page 29

Server system
Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional)
Code
Text
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
E1624
Lost power
supply
redundancy.
Check PSU
cables.
E1625
PS AC Current
E1626
Power Supply
Mismatch. PSU1
= ### W, PSU2
= ### W.
E1629
Power required
> PSU wattage.
Check PSU and
config.
E1632
FailSafe
event. Contact
support.
(continued)
Causes
Specified power supply is
attached to the system,
but it has lost its
AC input.
The power supply
subsystem is no longer
redundant. If the
remaining power supply
fails, the system will
shut down.
Power source is out of
acceptable range.
The power supplies in the
system are not the same
wattage.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
The processors and
memory have been
throttled to keep system
power consumption below
the maximum safe level
with current power supply
configuration.
Corrective Actions
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 155.
See "Troubleshooting
Power Supplies" on
page 155.
Check the AC power
source.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system's Getting
Started Guide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
About Your System