Figure 3-10. Removing and Installing a Redundant Power Supply
1
power supply
3
cable retention bracket
Installing a Redundant Power Supply
1 Verify that both power supplies are of the same type and have the same
maximum output power.
NOTE:
supply label.
2 If applicable, remove the power supply blank. See "Removing the Power
Supply Blank" on page 97.
3 Slide the new power supply into the chassis until the power supply is fully
seated and the release latch snaps into place. See Figure 3-10.
NOTE:
procedure, relatch it. For information about the cable management arm, see
the system's rack documentation.
4 Connect the power cable to the power supply and plug the cable into a
power outlet.
CAUTION:
Velcro strap.
96
Installing System Components
The maximum output power (shown in watts) is listed on the power
If you unlatched the cable management arm in step 1 of the previous
When connecting the power cable, secure the cable with the
1
2
locking tab
2
3