Table 1-2. LCD Status Messages (Optional)
Code
Text
E1000
Failsafe
voltage error.
Contact
support.
E1114
Ambient Temp
exceeds
allowed range.
E1116
Memory
disabled, temp
above range.
Power cycle
AC.
E1119
Chipset # temp
out of range.
Check
motherboard
heatsinks.
E1210
Motherboard
battery
failure. Check
battery.
E1211
RAID
Controller
battery
failure. Check
battery.
Causes
Check the system event
log for critical failure
events.
Ambient temperature has
a reached a point outside
of the allowed range.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Chipset temperature
reached a point outside
the allowed range.
CMOS battery is missing
or the voltage is outside of
the allowable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
See "Troubleshooting
System Cooling
Problems" on page 156.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 156.
If the problem persists,
see "Getting Help" on
page 181.
See "Troubleshooting
System Cooling
Problems" on page 156.
See "Troubleshooting the
System Battery" on
page 155.
Reseat the RAID battery
connector. See "RAID
Battery (Optional)" on
page 119, and
"Troubleshooting System
Cooling Problems" on
page 156.
About Your System