System Messages

System messages appear on the screen to notify you of a possible problem
with the system.
NOTE:
If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Table 1-3. System Messages
Message
Alert! iDRAC6 not
responding.
Rebooting.
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
40
About Your System
Causes
The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization. The
system will reboot.
The iDRAC6 has stopped
responding.
The iDRAC6 was remotely
reset while the system was
booting.
After AC recovery, the
iDRAC6 takes longer than
normal to boot.
Corrective Actions
Wait for the system to
reboot.
Remove AC power to the
system for 10 seconds and
restart the system.