Power Supply - Dell PowerEdge R415 Owner's Manual

Server system
Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional)
Code
Text
E1420
CPU Bus parity
error. Power
cycle AC.
E1421
CPU #
initialization
error. Power
cycle AC.
E1422
CPU # machine
check error.
Power
cycle AC.
E1610

Power Supply #

(### W)
missing.
Check power
supply.
E1614
Power Supply #
(### W) error.
Check power
supply.
E1618
Predictive
failure on
Power Supply #
(### W).
Check PSU.
28
About Your System
(continued)
Causes
The system BIOS has
reported a processor bus
parity error.
The system BIOS reported
a processor initialization
error.
The system BIOS has
reported a machine
check error.
Specified power supply
was removed or is missing
from the system.
Specified power supply
has failed.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
See "Troubleshooting
Power Supplies" on
page 155.
See "Troubleshooting
Power Supplies" on
page 155.
See "Troubleshooting
Power Supplies" on
page 155.

Hide quick links:

Advertisement

Table of Contents
loading