9.
Print a skew page to check the margins. The arrow on the top margin should be fully visible.
10.
Repeat steps 1 through 9 for Left Mrgn and Bottom Mrgn.
Note: The margins for the top, left and bottom are properly set when the arrows on the four arrows are
fully visible.

Scanner Registration

Go to the Reports menu and print a menu page. If the firmware version is build 67, follow the procedure below
but use use the guidelines shown in
registration with build 67 firmware" on page 3-8
support to obtain the latest firmware build. If the firmware is build 112 or later, follow steps 1 through 19 only.
The scanner registration function is used to set the left margin on the ADF and flatbed. The top, right, and
bottom margins are set automatically when the left margin is set. To set the registration, perform the following
steps:
1.
In the diagnostics menu, use the Up or Down keys to scroll to the Registration menu item.
2.
Press
to select the Registration menu item from the diagnostics menu.
3.
Use the Up or Down keys to scroll to the Scanner submenu item.
4.
Press
to select Scanner.
5.
Test Copy is the default menu item.
6.
Press
.
7.
If you are using the paper supplied with the service part, remove it from the tube and flatten it out.
8.
Place the sheet of light blue paper in the flatbed, or ADF. If the paper is going in the ADF, Insert the paper
with the curl down.
9.
Press
.
10.
Use the Up or Down keys to scroll between A4 and letter.
11.
Press
to print out a the test copy page. The MFP returns to ready mode.
12.
Reenter diagnostics.
13.
Reenter the Registration menu, and select the Scanner submenu item.
14.
Use the Up or Down keys to scroll to the FB Lft Mrgn, or ADF Lft Mrgn submenu item. Press
select the desired menu.
15.
Using the test copy printed earlier, use the rulers on the right and left sides of the page to adjust your left
margin.
16.
Use the up and down arrow keys to shift the left margin to its desired margin. Pressing the Up key moves
the margins to the left. Pressing the Down key moves the margins to the right.
17.
Press
to save the new setting.
18.
Scroll to Test Copy.
19.
Press
.
20.
Use the Up and Down keys to scroll to A4 or Leter (build 122 or later).
21.
Press
. Atest copy prints.
22.
Inspect the margins. The scanner registration is properly set when the edges of the paper line up with 0 on
all the test copy rulers.
23.
Repeat steps 12 to 22 until the correct registration values are set.
"Using the test copy page rulers to determine correct scanner