Fuji Electric FEH300b Hardware User Manual page 37

Display attached controller
Table of Contents

Advertisement

• Tighten terminal screws on the power supply terminal block of the display unit with the following torque.
Use a power supply cable within the range shown below.
Types
Screw
size
NP5M0101-5H4
NP5M0101-4H4
M3.5
NP5N0011-5H4
NP5N0011-4H4
NP5M0101-3H4
M3.5
NP5N0011-3H4
• The power supply terminal block of the controller unit uses M3 terminal screws. Their tightening torque should be
0.5 to 0.6 N·m.
Select the appropriate cable, and crimp terminals to be used. Applicable cable sizes and crimp terminals are as
follows:
Maker
Form
Round
AMP
terminals
Round
terminals
Nichifu
Angle edge
terminals
Round
JST
terminals
Round
terminals
NTK
Angle edge
terminals
3-2 Power Supply Cable Wiring
Tterminal screw
Tightening
torque
3.7mm
0.8N· m
8mm
or less
3.7mm
1.2N· m
7.1mm
or less
Cable size
Types
AWG
36467
34104
22 to 18
34105
0.3-3
24 to 20
0.3-3N
1.25-3
1.25-3N
1.25-3S
22 to 16
1.25-3.5N
1.25-3.5S
2-3N
16 to 14
0.3Y-3
24 to 20
1.25Y-3
1.25Y-3N
22 to 16
1.25Y-3S
1.25Y-3.5
2Y-3
16 to 14
2Y-3.5S
AT1-10
22 to 16
AT2-10
16 to 14
SRA-20-3.2
22 to 18
SRA-20T-3.2
0.4-3
26 to 22
1.25-3
VR1.25-3
22 to 16
VD1.25-3
VD2-3S
16 to 14
3-3
Crimp-style terminal
8mm
or less
7.1mm
or less
2
mm
2
0.3 to 0.8 mm
2
0.2 to 0.5 mm
0.3 to 1.3 mm
2
1.3 to 2.0 mm
2
2
0.2 to 0.5 mm
2
0.3 to 1.3 mm
2
1.3 to 2.0 mm
2
0.3 to 1.3 mm
2
1.3 to 2.0 mm
0.3 to 0.8 mm
2
0.2 to 0.3 mm
2
2
0.3 to 1.3 mm
2
1.3 to 2.0 mm
Power
Cable
3.7mm
AWG18 - 16
3.7mm
AWG16 - 14
Terminal dimensions

Advertisement

Table of Contents
loading

This manual is also suitable for:

@e.terminal for mc

Table of Contents