NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH
From the Port settings menu, the configuration of each port can be viewed and changed.
Setting
Description
Port name
Change the port name
Port type
Host or User
In-band disconnect
Select characters to use for in-
sequence
band disconnect sequence
Connection
Time left before connection will be
Timeout
broken due to receiver inactivity
Serial settings
Display serial settings menu
Modem settings
Display modem settings menu
View port data
View the last 508 characters
buffer
received and transmitted to/from
the port
Clear port data
Clear the data buffer for the
buffer
selected port
VT100 displaying
Modify the displaying extra delay
delay
Reset Port settings
Restores factory default port
to default
settings
When [3] is pressed to change the in-band disconnect sequence, the choices provided are 0, 1, 3, or T. Pressing a [T] will bring
up a Control code list containing key sequences used for 1-character sequences, and the ASCII codes associated with each.
(See Fig. 10) To set a 1-character sequence, press [1], then the code from the table associated with the desired sequence.
Note: If the 3-character disconnect sequence is enabled, the string: [CR][LF]<3-char sequence>[CR][LF] has to be
received to break the connection (7 characters).
(ASCII Carriage Return and Line Feed)
FYI: If the 1-character sequence is
selected, the connected device will
not receive the disconnect character.
If the 3-character sequence is
selected, it will be sent to the
connected device, prior to breaking
the connection.

Figure 11- Control Codes for in-band disconnect sequence

-
When selecting each new port setting values, press [Esc] or [Spacebar] to cancel, or press [Enter] to save.
-
Press [>] (greater than symbol) to display the current settings for the next port.
-
Press [<] (less than symbol) to display the current settings for the previous port
-
Press [Esc] or [Spacebar] to return to the "Administrator main menu"
Value
Max. 15 characters
H or U
1 + code for 1-character sequence (see Fig. 6 below)
3 + desired characters for 3-character sequence
0- for no disconnect sequence
T- display Control code list
0-90 minutes.
never timeout.
N/a
N/a
N/a
N/a
0 = None,1 = normal, 2 = double, or 3 = triple
"None" value can be used if the display is faster (i.e. with a
terminal emulator, like HyperTerminal, running on a PC); the
other values are useful if real terminals or slower serial
devices are used as user/administrator consoles.
A confirmation "Y" will be required
The [CR] and [LF] ASCII characters stand for 13 and 10 decimal codes
respectively.
15
If 0 is selected, the connection will

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serimux-term-cs-16Serimux-term-cs-8