NEC NEAX 2000 IVS Installation Manual page 169

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

NAP 200-010
Sheet 2/3
System Initialization and System Data
Entry
4. System Data Entry
There are two methods for data entry, both of which employ a CAT or a MAT.
1.3. CAT
term
Any D
can be assigned as a CAT terminal through programming. The D
telephone when it is not in CAT mode. If the system is initialized by "A" (Resident System Program), every
term
D
will be able to go into CAT mode. If the system is initialized by "B" (All Clear), only LEN0000 is assigned
as a CAT port (the DLC card must be installed in slot LT00).
term
To use a D
as a CAT, follow the procedures shown below.
To set CAT mode:
(1) Press
TRF
(2) Press
CNF
CNF lamp flashes
(3) Press
*
CNF lamp is off
(4) Press
TRF
(5) Press
CNF
CNF lamp flahses
(6) Press
#
CNF, SPKR, ANS lamps are lit
"CAT MODE" is displayed on the LCD
(7) Press
ST
"COMMAND = -" is displayed on the LCD
Steps 1 through 6 need to be completed within four (4) seconds.
Note:
CHAPTER 3
Page 152
Revision 2.0
ND-45492 (E)
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
term
can still be used as a regular