NEC NEAX 2000 IVS Installation Manual page 166

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

NAP 200-009
Sheet 5/6
Installation of Back up MP System
STEP 7:
On side 1 (MP1) place SW4 in the DOWN position.
Ensure that SW2 1-8 are OFF and Side 0 (MP0)SW2-8 is ON.
Start programming Office Data from either the CAT or MAT.
STEP 8:
When Office Data is completed, set SW2-8 OFF on Side 0 (MP0) and on side 1 (MP1) Reset (push)
SW1. The run LED on side 1 (MP1) will light solid. After about 5 minutes, the run LED on the MP1
will flash (3 seconds on, 1 second off). The system data stored in the MP0 card is copied to the MP1
card.
After about 30 minutes, the Run LED lamp flashing pattern on side 1 (MP1) is changed to 1 second on,
1 second off.
The MP1 card starts up as the stand-by MP.
Note 1:
The Compact serial number, Advantage serial number, CPN serial number and System CPU ID code must
be loaded separately on each MP.
For example:
MP0
CPU # 0123456789101
Compact # 0123456789
Advantage # 0123456789
IVR ID # 0123456789
MP1
CPU # 9876543210000
Compact # 9876543210
Advantage # 9876543210
IVR ID # 9876543210
ND-45492 (E)
CHAPTER 3
Page 149
Revision 2.0

Advertisement

Table of Contents
loading

Table of Contents