Table 3 Alphabetical List of Commands
Command
*CLS
*ESE?
*ESE <num>|MIN|MAX|DEF
*ESR?
*IDN?
*OPT?
*RST
*SRE?
*SRE <num>|MIN|MAX|DEF
*STB?
*TST?
CALCulate:AVERage:CLEar
CALCulate<chn>:AVERage<n>:DATA?
CALCulate:AVERage<n>:TYPE?
CALCulate<chn>:CONVert:CATalog?
CALCulate<chn>:CONVert:COPY<dest chn>|ALL
CALCulate<chn>:CONVert:NAMe?
CALCulate<chn>:CONVert:NAMe <conv>
CALCulate<chn>:CONVert:PARameter:CATalog?
CALCulate<chn>:CONVert:PARameter:VALue?
[<param>|ALL]
CALCulate<chn>:CONVert:PARameter:VALue
<param>,<num>[,< param>,<num>...]
CALCulate:CONVert:PRINt [<chn>|ALL [,<port>]]
CALCulate<chn>:CONVert:SNUMber?
CALCulate<chn>:CONVert:SNUMber <seri>
CALCulate<chn>:CONVert:TEST? <res>|<volt>
Description
Clears the status registers
Returns the Event Status Enable Register
Sets the Event Status Enable Register
Returns the Event Status Register
Returns the instrument identification string that indicates
the manufacturer, model number, serial number, and firm-
ware version
Returns a list of installed input card types
Sets the instrument operating parameters to defined
conditions
Returns the Service Request Enable Register
Sets the Service Request Enable Register
Returns the Status Byte Register
Performs a self-test and reports any errors that are found
Clears the statistical functions for all channels
Returns the value of a statistical calculation for the speci-
fied channel
Returns the keyword for the specified calculation type
number
Returns a list of conversion types available for the speci-
fied channel
Copies the conversion type, sub-ranges (ITS-90), serial
number, and characterization coefficients from one chan-
nel to another
Returns the name of the selected conversion type for the
specified channel
Sets the conversion type by name for the specified
channel
Returns the names of the probe characterization parame-
ters used with the selected conversion type for the speci-
fied channel
Returns the value for the specified or All conversion pa-
rameters for the specified channel
Sets the value of one or more conversion parameters for
the specified channel number
Returns the conversion parameters for the specified
channel
Returns the probe serial number for the specified channel Section 8.4.4
Sets the probe serial number for the specified channel
Tests the temperature conversion for the specified channel Section 8.4.4
8 Digital Communications Interface
Interface Commands
Refer To
Section 8.4.12
Section 8.4.12
Section 8.4.12
Section 8.4.12
Section 8.4.8
Section 8.4.8
Section 8.4.8
Section 8.4.12
Section 8.4.12
Section 8.4.12
Section 8.4.12
Section 8.4.1
Section 8.4.1
Section 8.4.1
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
Section 8.4.4
79