Note: The terms flashing, blinking, and solid used in
Flashing: LED is flashing randomly.
Blinking: LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid: LED is on steady and not pulsing.
Table 4-1 LANVIEW LEDs
LED
Color
CPU
Off
Red
Amber
Green
State
Power disconnected.
Solid. Boot-up failed.
Blinking. Diagnostics have
failed.
Solid. Diagnostics are running. If the LED remains amber for more than
Blinking. Code image is being
downloaded.
This also notes when the
configuration is being saved to
member units. (This occurs
every 15 minutes and when the
user enters the "save config"
command).
Solid. System is fully
functional.
Blinking. Boot-up in process.
Table 4-1
indicate the following:
Recommended Action
If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:
1. Make sure there is power at the power
source (AC source and RPS if
applicable).
2. Replace the power cord with a known
good one or check the continuity of the
power cord.
3. If the SecureStack A2 still does not
power up, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Contact Enterasys Networks for technical
support.
several minutes, contact
Enterasys Networks for technical support.
None.
None.
None.