EP setup
EP Defaults
Restores all EP settings to factory default values. Selections are Restore
and Do Not Restore.
Fuser Temperature (Fuser Temp)
Changing this setting can reduce paper curl or melting of some letterhead
images. Selections are Normal (default), Lower, and Lowest.
Transfer
The transfer can be adjusted to Low, Medium, or High. The default setting
is Medium.
Print Contrast
The print contrast can be adjusted to Low, Medium, or High. The default
setting is Medium.
Charge Roll
The charge roll can be adjusted to Low, Medium, or High. The default
setting is Medium.
Gap Adjust
Adjusts the minimum gap between sheets during printing. This setting
reduces speed (pages per minute), but can be used to reduce curl of printed
media and improve stacking in the output bin.
Range is 0 (default) to 255. Adjusting by one results in 9 mm of increased
gap.
Diagnostic aids—E340 and E342n
4511-xxx
3-31