Network

Menu item
History
Mark History
History Mode
Dump
NVRAM
Reinit
NVRAM
Meditech
Mode
Use setting to
Print history of errors.
Press and hold
the lights flash to print.
Append a tag to the
history report to indicate
the most recent crashes.
Post the 976 error code to
the user each time it
occurs. The default
(modified) internally
resets the posting but
records it in the crash
history. A substantial
number of consecutive
errors result in posting
976.
Print a hex dump if the
network NVRAM partition.
Press and hold
the lights flash to initiate
this action.
Rest the network NVRAM
to factory defaults.
Press and hold
the lights flash to initiate
this action.
Prevent the network card
from accepting more than
one 9100 mode
connection at a time.
Diagnostic aids—E238, E240, and E240n
Value
until
Mark
Do not mark (default)
Modified (default)
Every time
until
until
Yes
No (default)
4511-xxx