Front Panel Connectors; Back Panel Connectors - Zhone IMA CS-200 System Reference Manual

Imacs-200 series
Table of Contents

Advertisement

Running Head
Connector Types
Connector Name
Connector Type
Ethernet
RJ45
Serial
RJ45
Connector Name
Connector Type
Voice
50 pin amphenol
Voice
50 pin amphenol
Voice
50 pin amphenol
Alarm
RJ45
High Speed Data
DB25 female
Sub Rate Data
RJ45
OHSU1 and
Two ST optical
OHSU2
connector pairs
Enet
RJ45
T1/E1
RJ45
48VDC (+-G) 1.5A
3 position
Max
(plugs included
125VDC (label)
with kit of parts)
120/220VAC
AC receptacles
OWAN1 OWAN2
Two ST optical
Connectors
Earth Ground
2-6
Table 2-2. Front panel connectors
Description
Ethernet port for remote management over IP.
Asynchronous craft port for local management.
Table 2-3. Back panel connectors
Description
Four E&M lines, transmit only (to) in the introductory offering of the
IMACS-200. Each line utilizes eight leads from the connector.
Four FXS Tip-and-Ring pairs. Each line utilizes two leads from the
connector.
Alarm input contacts are provided in this connector. There are four
available contacts, each utilizing two leads from the connector.
Alarm outputs to an external alarm system.
Two V.35 high speed data port connectors.
Five subrate data (SRU) ports
The IMACs-200 can be configured with an Optical High Speed Unit
with two pairs of optical connections.
Ethernet port for remote management over IP. This port is disabled for
this initial release of the product.
Four transmit and receive pairs for T1 network access. E1 will be
provided in a later release.
For DC power inputs. IMACS-200 can have two DC inputs.The
cables used to connect the power to the chassis should be 20 to 18
gauge solid wire.
Power input 1.0A 50/60Hz when external AC voltage is used to
power the unit.The IMACS-200 can have two such supplies.
The IMACs-200 can be configured with an Optical WAN Unit with
two optical connections.
Permanent Earth Ground Connection.
a single connection to the provided earth ground screw, and
connect to a ground source.
Model No.
System Installation
Use 14 gauge solid wire for
System Installation