Table 10-2. OHSU port Setting Options and Defaults
Parameter
STATE
WAN/SRV
MODE
TS
RATE
TX CLOCK
LOCAL LB
STATE
The State setting determines whether the port is active or inactive. An inactive port does not
occupy time slots on a WAN link. Set State to standby (stdby) for ports you are not using or
have not yet configured. Set it to active (actv) for ports that are ready for use.
WAN
The WAN setting identifies the WAN or OWAN port to which the output of this port is
directed. The options are wan-1 to wan-4, and owan-1 to owan-4.
MODE
The Mode parameter appears for information only. The OHSU is fixed in the MUX mode.
OHSU Ports
Table 10-1. OHSU port Main Screen Actions
User Options
stdby actv
none
wan-1 wan-2 wan-3 wan-4
owan-1 owan-2 owan-3 owan-4
mux
table (up to 12 TS)
64k
int (mux MODE)
off user net
Function
stdby
none
mux
no assignment
64k
int
off
Default
10-3