Zhone IMA CS-200 System Reference Manual page 167

Imacs-200 series
Table of Contents

Advertisement

Action
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e., test status).
Copy
Copies the contents of the current column to the next column. Useful if you
change a lot of entries in one column and wants to repeat those changes in
subsequent columns.
Test
Access is given to the test screen
taBs
Index into the signaling conversion screen.
Main
Returns to the System Main Screen. If you make changes to settings and do
not save them, you will be prompted to save or lose changes.
Table 7-2, "Main Screen Option Settings and Defaults," on page 7-7 summarizes the
configuration settings for the E&M port, along with the available and factory-default option
settings. The parameters and settings are also described in the following paragraphs.
Table 7-2. Main Screen Option Settings and Defaults
Parameter
STATE
stdby
WAN/SRV
none
owan-3 owan-4
TS
01-24 or 01-31
MODE
to e&m I e&m II e&m IV e&m V
Rx TLP
-16.3 dB to +7.5 dB
Tx TLP
-16.3 dB to +7.5 dB
CODING
u-law
LB
off
PATTRN
none
SIG CONV
n/a off on
Notes:
1. The extended setting range for the IMACS-200 E&M port is from -16.3 to +7.5 dB.
2. When a WAN or SRV port has not been selected, or when the mode it to, the default
for Signal Conversion is n/a. When the mode has been selected to be e&m, then the
default is off.
E&M Ports
Table 7-1. Main Screen Actions
User Options
actv
wan-1 wan-2 wan-3 wan-4 owan-1 owan-2
a-inv
dgtl
anlg
D-mW
Function
Notes
Default
stdby
none
01
to
0
1
0
u-law
off
none
23
off
7-7