Voice Diagnostics - Zhone IMA CS-200 System Reference Manual

Imacs-200 series
Table of Contents

Advertisement

System Testing and Diagnostics

14.3.2 Voice Diagnostics

The software-initiated diagnostics supported are voice ports include the setting of both analog
and digital loopbacks toward the network and the generation of Quiet Tone and a Digital
MilliWatt signal on a port-by-port basis. The operator can also monitor and set the state of the
analog leads of any FXS or E&M port. They can set and monitor the state of the ABCD
signaling bits of the digitized voice signal. In cross-connect system, test functionality also
includes the ability to generate test tones (300Hz, 1 kHz and 3 kHz) and transmit those toward
the user side or the network side of the system. The table below shows detailed information
on the diagnostic capabilities of the Voice ports.
On-port loopbacks
Analog Toward Network
Digital Toward Network
Signaling Manipulation
Set Status of Analog Interface Leads
Set Transmit ABCD Signaling Bits
Set Receive ABCD Signaling Bits
Monitor Status of Analog Interface
Leads
Monitor Status of Transmit ABCD
Signaling Bits
Monitor Status of Receive ABCD
Signaling Bits
Tone Generation
Tone Supported
300 Hz
1 kHz
3 kHz
Quiet Tone
Digital MilliWatt
Tone Direction
Toward User
Toward Network
Diagnostics
User port Diagnostics
4-wire E&M 2-wire FXS
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes*
Yes*
Yes
Yes
Yes
Yes
Yes
Yes
Yes*
Yes*
Yes*
Yes*
Yes*
Yes*
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
14-3