4.3.4 HTTP Client Settings
4.3.4.1 HTTP Client Settings
HTTP Version
Description
Value Range
Default Value
Configuration File Reference
HTTP User Agent
Description
Value Range
Default Value
Configuration File Reference
4.3.4.2 HTTP Authentication
Authentication ID
Description
Value Range
Default Value
88
Administrator Guide
Selects which version of the HTTP protocol to use for HTTP
communication.
•
HTTP/1.0
•
HTTP/1.1
Note
•
For this unit, it is strongly recommended that you select [HTTP/
1.0]. However, if the HTTP server does not function well with
HTTP/1.0, try changing the setting [HTTP/1.1].
HTTP/1.0
HTTP_VER (Page 197)
Specifies the text string to send as the user agent in the header of HTTP
requests.
Max. 40 characters
Note
•
You cannot leave this field empty.
•
If "{mac}" is included in this field, it will be replaced with the
unit's MAC address in lower-case.
•
If "{MAC}" is included in this field, it will be replaced with the
unit's MAC address in upper-case.
•
If "{MODEL}" is included in this field, it will be replaced with the
unit's model name.
•
If "{fwver}" is included in this field, it will be replaced with the
firmware version of the unit.
Panasonic_{MODEL}/{fwver} ({mac})
HTTP_USER_AGENT (Page 197)
Specifies the ID for the User account. If set, this name must be entered
to access the Web user interface at the User access level.
Max. 127 characters
Not stored.
Document Version